SCANNER AND CABLE TERMINATIONS
SCANNER PINOUT CONNECTIONS
IS1650-14
RS232
Pin Function
1 Ground
2 RS232 Transmit Output
3 RS232 Receive Input
4 RTS Output
5 CTS Input
6 DTR Input
7 Reserved
8 Reserved
9 +5VDC
The IS1650 scanner interfaces
terminate to a 10-pin, RJ45
Female Socket. The serial
number label indicates the
interface enabled when the
scanner is shipped from the
factory.
10 Shield Ground
IS1650-47, Keyboard Wedge &
Stand-Alone Keyboard
Pin Function
1 Ground
2 RS232 Transmit Output
3 RS232 Receive Input
4 PC Data
5 PC Clock
6 KB Clock
7 PC +5V
8 KB Data
9 +5VDC
10 Shield Ground
Figure 19.