SCANNER AND CABLE TERMINATIONS
Scanner Pinout Connections
The IS3480 scanner interfaces terminate to a 10-pin modular socket.
The serial # label indicates the interface enabled when the scanner is shipped
from the factory.
Figure 15.
IS3480-47 Keyboard Wedge
and Stand-Alone Keyboard
IS3480-41
RS232C and Light Pen Emulation
Pin Function Pin Function
1 Ground 1 Ground
2 RS232 Transmit Output 2 RS232 Transmit Output
3 RS232 Receive Input 3 RS232 Receive Input
4 PC Data 4 RTS Output
5 PC Clock 5 CTS Input
6 KB Clock 6 DTR Input/LTPN Source
7 PC +5V 7 Reserved
8 KB Data 8 LTPN Data
9 +5VDC 9 +5VDC
10 Shield Ground
10 Shield Ground
IS3480-38
RS232 Low Speed USB
IS3480-11
IBM 468X/469X
Pin Function Pin Function
1 Ground 1 Ground
2 RS232 Transmit Output 2 RS232 Transmit Output
3 RS232 Receive Input 3 RS232 Receive Input
4 RTS Output 4 RTS Output
5 CTS Input 5 CTS Input
6 D+ 6 DTR Input
7 V_USB 7 IBM B-Transmit
8 D- 8 IBM A+ Receive
9 +5VDC 9 +5VDC
10 Shield Ground
10 Shield Ground