SCANNER AND CABLE TERMINATIONS
IS3480-9 OCIA
Pin Function
1 Ground
2 RS232 Transmit Output
3 RS232 Receive Input
4 RDATA
5 RDATA Return
6 Clock In
7 Clock Out
8 Clock in Return / Clock out Rtrn
9 +5VDC
10 Shield Ground
IS3480-104 RS232, RS232 TTL, or Laser Emulation
Pin Function
1 Ground
2 RS232 Transmit Output
3
RS232 Receive Input
4
RTS Output (TTL RS232) / Flip Sense
5
CTS Input (TTL RS232) / Trigger Emulation Output
6
DTR Input (TTL RS232) / Scan Enable
7
Receive (TTL RS232) / Good Read
8
Transmit (TTL RS232) / Scan Data
9
+5VDC
10
Shield Ground
Insulation Displacement Connector
(IDC), 6-pin Utility Connector
Pin Function
1 Aux +5V
2 Good Read
3 Aux Beeper
4 Aux Active
5 Aux Out
6 Aux Ground
Figure 16.
Vista de pagina 43